The system of remote restoration of sewage systems

A remote-controlled recovery system for pipes with a diameter of DN100-150 at a distance of up to tens of meters from the entry point. Forget about dismantling, approvals, and restoring landscaping. SP!RES changes the rules of the game. We have created a solution for areas that previously could not be repaired without large-scale destruction.

Process technology: from the input to the finished pipe

01

Preparation and broaching

A special liner is placed inside the system and stretched in a straight line using a cable to the repair site.

02

Orientation and inversion

The device is inserted into the main channel and focuses on the problematic branch.

03

Polymerization

A liner is supplied through the hose. The calibration sleeve inflates, tightly pressing the new liner material against the walls of the old pipe.

04

Monitoring and completion

Built-in sensors monitor temperature and pressure in real time until a durable new pipe is formed inside the old one.

Working conditions and technical capabilities

The SP!RES system is designed for all-season use and is independent of external factors.

Working environment

Sanitation is carried out regardless of the direction of wastewater flow and the presence of water in the pipe.

Service life

Sanitation is carried out regardless of the direction of wastewater flow and the presence of water in the pipe.

Temperature regime

Sanitation is carried out regardless of the direction of wastewater flow and the presence of water in the pipe.

Pipe type

Sanitation is carried out regardless of the direction of wastewater flow and the presence of water in the pipe.

Compatibility

What diameters do we work with?

SP!RES is a specialized solution for the most demanded diameters of house and private connections.

Get a consultation

DN 100

The device is inserted into the main channel and starts the inversion process.

DN 125

The device is inserted into the main channel and starts the inversion process.

DN 150

The device is inserted into the main channel and starts the inversion process.

DN 100

The device is inserted into the main channel and starts the inversion process.

A patented technology with a legally significant result

SP!RES against traditional methods

Why are municipalities and contractors around the world switching to SP!RES? Because we solve a problem, not create new ones.

Criteria Traditional method (excavation) The SP!RES method
The need for excavationDismantling and opening of the ground is requiredComplete absence
Access to a private areaRequired, requires approvalNot required
Repair timeDays and weeksWatch
Restoration of landscapingRequired (asphalt, lawns)Not required
The social factorNoise, residents' discontent, closuresCompletely unnoticeable by the townspeople
StaffA team of workers is requiredUp to 3 trained operators
ReportingPhoto fixing, actsDigital PDF report with parameters
The need for excavationDismantling and opening of the ground is requiredComplete absence